LAST EDITED ON Feb-09-04 AT 10:48 PM (CDT) >I converted a steel sleeve RC FP .20 for a Super Clown by
>fitting the OS venturi (.260) and NVA (.135) and wondered if
>this was truly a good setup since I'm starting to fly in a
>more demanding manner. It seems that the venturi is used on
>various size engines which leads me to believe that it may
>not hit the mark for the little .20. Also, are there any
>other easy mods to dial this engine in? Stock muffler
>currently.
I don't know about the steel-liner motors. I do know that the ABN stockers, including stock .257 venturi and stock spraybar (and for that matter stock muffler with baffle in place), run perfectly well - in fact so well that I would strongly discourage anyone from significant deviation. It's more than satisfactory for me, and I'm pretty picky - I figure if I can get 540 point patterns with a 20FP and a Skyray, it's probably good enough for a Super Clown. I really like the silky-smooth power delivery.
This size venturi seems to work much better on the 20 than the 25, by the way. On the 25 its seems too large, on the 20 it seems just fine.
I would encourage you to try it with a 9-4 APC, and a good 10 or 15% fuel. DO NOT bog it down with more diameter or pitch - it will be very, very unhappy. If you must use oversized props, then maybe you do need a smaller venturi.
>Also, with a 2.0 oz. GRW profile uniflow tank, there are two
>forward facing ports outboard on the upper and lower wedge
>panels respectively. I assume the upper one is the uniflow
>(no diagram). This location puts it right behind the engine.
>Run it like this? Route to clean air? Or use muffler
>pressure? I'm willing to experiment, but I'll take a hint
>from others with lessons learned.
I have no idea about the GRW tanks, and which pipe is which. Assuming you do figure it out (it's easy enough to just fuel it up and see where fuel comes out at various angles), you can try using muffler pressure into the uniflow, but I found that it would work only about 80% of the time. The other 20%, it would go about half a tank and take off lean. Vented to air worked OK.
After Godzilla's valuable observations about clunk tanks at the 2002 NATs, I tried a pretty much stock Sullivan clunk on the 20FP, and it seems to work well. I set it up stock, with the exception of a third fill tube, as a suction tank. I put the muffler pressure to the vent. It seems to work quite well, and the tanks are both cheap and widely available. You have to be a little bit careful about not getting it too lean at the beginning of the flight, but it's not that hard. I think it's worth a try.