Good Lord! Unpredictability is one of the tools in my bag and here Derek has me completely figured out. This cannot be a good thing.
Yes, of course I have used Tettra tanks, in both 4- and 3-ounce sizes, on my ARF Flite Streak/20FP combinations. However, I had less than sterling results. Stupid, stupid, **stoopid** mistake, in a rush I grabbed a fuel filter known to be suspect, plugged it in, proved once again how highly durable are the 20FPs.
As I had a whole stack of various tanks to fiddle with, off came the Tettra tanks, on went Du-Bro SS-4s.
I have a defense, even if some will reject it out of hand: A good bit of the idea behind Brett's initial thinking, and a point of view I have since adopted, is that not only do we have access to a superior *system* in the 20FP tune-up as proven and then freely supplied by Brett, there is opportunity to assemble this killer setup from off-the-shelf components.
There's more to the story, now that tempers have calmed somewhat I will address it fully in the next day or so, but it should be obvious there is a crying need for a system approach which is not only highly effective, demonstrates the type of power delivery so sought after by our top fliers, **and** can be put together in a weekend without ordering any trick parts at all by mail.
Thus my current emphasis on using bottom-feeder tanks, plumbing just like the instructions, piping muffler pressure to them and flying. As mentioned before, both Pylon RST-4s and Du-Bro SS-4s are mounted to the inboard side of fuselage, and I have taken to liking them installed with narrow side of tank against the fuselage. Yeah, they work fine either way, but are slightly easier to mount on my models and with existing bracketry, plus plumbing is a little easier, a bit more reliable.
As the Tettra tanks, while readily available from Central Hobbies, do require mail-order sourcing, and are not at all cheap, I have been holding them in abeyance for the time when a lot more of us are on the same page in this 400-inch profile/20FP adventure.
Derek, tell me about the fuel pickup you are using. I know of guys running a length of silicone tubing which has cuts along its length, but I just terminate the hard tubing with a short piece of silicone to protect bladder from hard edges of tube. Tubing is installed such that it bends toward outboard side of tank, ending at about the mid-point of tank.
Also, as I am mounting Tettra tanks inboard, they are situated such that pressure inlet faces "up," simplifying the plumbing a little.
For those just reading along, do notice please, Derek's comment that the 20FP supplies less power than the 25FP, **speed regulation is significantly better."** Here's a guy who gets it, folks.
Just last night I was talking with a new friend and he's been though the 20FP discussions, proposes using a Super Combat Streak in Classic but with a 25FP. No, no!! If you're gonna sign on to the program, don't adulterate it by "going for more power."
Incidentally, several years ago I built a pretty nice Combat Streak (barenekd plans) for my 25FP. Nothing more than a fun sport model. Fitted it with a 20FP two weeks ago, can't wait to give it a try. Yep, may even fly it in Classic, just depends upon how much fun it is.
Oh, and thanks to jaco for the accurate description of Tettra tanks, the primary application and the picture.
Dan
P.S. Phil, I have not forgotten your request for sage advice, your whining about a shakey profile. The Tettra tanks might be worth trying. Or, as you are not known for spending money any too freely, DesignMan has had plenty of good input when it comes to "balloon" tanks.